Sl.
No.
Parameter Item Type /
Group
Item Name Alias Name Range No. of
Points for Calibration
Limitation /
Condition
Calibration
Chargesper Item (Rs.)
Additional
Charges Rs.
Description
for Additional Charges
Remarks,
if any
1 AC High Current Ratio Current Transformer Standard CT   Upto 1000 A 4 At 50 Hz 9500 7100 For each additional ratio & each additional burden 4 calibration points means 4 percentages of single ratio only
i.e. Single ratio at 4percentages
i.e. at 5%, 20%, 100% and 120% Tuning / Adjustment Charges extra @25%
2 AC High Current Ratio Current Transformer Standard CT   Above 1000 Aupto 2500A 4 At 50 Hz 11800 9300 For each additional ratio & each additional burden 4 calibration points means 4 percentages of single ratio only
i.e. Single ratio at 4percentages
i.e. at 5%, 20%, 100% and 120% Tuning / Adjustment Charges extra @25%
3 AC High Current Ratio Current Transformer Standard CT   Above 2500A Upto 5000 A 4 At 50 Hz 18900 12600 For each additional ratio & each additional burden 4 calibration points means 4 percentages of single ratio only
i.e. Single ratio at 4percentages
i.e. at 5%, 20%, 100% and 120% Tuning / Adjustment Charges extra @25%
4 AC High Current Ratio Current Transformer Standard CT   Above 5000A Upto 10000 A 4 At 50 Hz 23500 15800 For each additional ratio & each additional burden 4 calibration points means 4 percentages of single ratio only
i.e. Single ratio at 4percentages
i.e. at 5%, 20%, 100% and 120% Tuning / Adjustment Charges extra @25%
5 AC High Current Ratio C T Test Set CTTS (part of AITTS / ITTS)   5 A & 1 A 4 At 50 Hz 47200 26200 For each additional secondary Current Upto 4 ratios for single secondary current. Tuning/Adjustment
Charges extra @25%
6 AC High Voltage Ratio Voltage Transformer Standard PT/ Standard Capacitor with EPD   Upto 1 kV 3 At 50 Hz 11500 7600 For each additional ratio & each additional burden 3 calibration points means 3 percentages of single ratio only
i.e. Single ratio calibration at 80%, 100% & 120%. Tuning / Adjustment
Charges extra @25%
7 AC High Voltage Ratio Voltage Transformer Standard PT/ Standard Capacitor with EPD   Above 1 kV and upto 11 kV 3 At 50 Hz 15900 11000 For each additional ratio & each additional burden 3 calibration points means 3 percentages of single ratio only
i.e. Single ratio calibration at 80%, 100% & 120%. Tuning / Adjustment
Charges extra @25%
8 AC High Voltage Ratio Voltage Transformer Standard PT/ Standard Capacitor with EPD   Above 11 kV and upto 22 kV 3 At 50 Hz 23600 15900 For each additional ratio & each additional burden 3 calibration points means 3 percentages of single ratio only
i.e. Single ratio calibration at 80%, 100% & 120%. Tuning / Adjustment
Charges extra @25%
9 AC High Voltage Ratio Voltage Transformer Standard PT/ Standard Capacitor with EPD   Above 22kV and upto 33 kV 3 At 50 Hz 32500 24100 For each additional ratio & each additional burden 3 calibration points means 3 percentages of single ratio only
i.e. Single ratio calibration at 80%, 100% & 120%. Tuning / Adjustment
Charges extra @25%
10 AC High Voltage Ratio Voltage Transformer Standard PT/ Standard Capacitor with EPD   Above 33kV and upto 100 kV 3 At 50 Hz 80300 32500 For each additional ratio & each additional burden 3 calibration points means 3 percentages of single ratio only
i.e. Single ratio calibration at 80%, 100% & 120%. Tuning / Adjustment
Charges extra @25%
11 AC High Voltage Ratio P T Test Set PTTS (part of AITTS / ITTS)   110 V & 110 V/sqrt(3) 3 At 50 Hz 47250 26200 For each additional secondary Voltage Upto 3 ratios for single secondary voltage. Tuning/Adjustment
Charges extra @25%
12 AC High Voltage TLMS TLMS   Upto 50 kV   At 50 Hz 71400 46200 For each additionalphase Tuning/Adjustment Charges extra @50%
13 AC High Voltage TLMS TLMS   Upto 100 kV   At 50 Hz 142800 75600 For each additionalphase Tuning/Adjustment Charges extra @50%
14 AC High Voltage TLMS TLMS   Upto 200 kV   At 50 Hz 210000 120700 For each additional phase For each phase. Tuning/Adjustment Charges extra @50%
15 AC High Current Current Probe, kA Meter,AC High Current Source Current Probe, kA Meter, AC High Current Source Clamp Meter,Tong Tester Upto 1000 A   At 50 Hz 16800 7100 For each additional range upto 8 calibration points
16 AC High Current Current Probe, kA Meter, AC High Current Source Current Probe, kA Meter, AC High Current Source Clamp Meter,Tong Tester Upto 2500 A   At 50 Hz 23600 9300 For each additional range upto 8 calibration points
17 AC High Current Current Probe, kA Meter, AC High Current Source Current Probe, kA Meter, AC High Current Source Clamp Meter,Tong Tester Upto 5000 A   At 50 Hz 37800 12600 For each additional range upto 8 calibration points
18 AC High Voltage H V Break-down Test Set/ AC High Voltage source H V Tester   Upto 10 kV   At 50 Hz 28800      
19 AC High Voltage H V Break-down Test Set/ AC High Voltage source H V Tester   Upto 50 kV   At 50 Hz 47250 26200 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
20 AC High Voltage H V Break-down Test Set/ AC High Voltage source H V Tester   Upto 100 kV   At 50 Hz 80300 32500 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
21 AC High Voltage H V Break-down Test Set/ AC High Voltage source H V Tester   Upto 150 kV   At 50 Hz 110000 48300 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
22 AC High Voltage H V Break-down Test Set/ AC High Voltage source H V Tester   Upto 200 kV   At 50 Hz 137500 64000 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
23 AC High Voltage Electrostatic Voltmeter, Kilo Volt Meter Electrostatic Voltmeter, Kilo Volt Meter, HV Divider kV Meter Upto 50 kV   At 50 Hz 47250 26200 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
24 AC High Voltage Electrostatic Voltmeter, Kilo Volt Meter Electrostatic Voltmeter, Kilo Volt Meter, HV Divider kV Meter upto 100 kV   At 50 Hz 80300 32500 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
25 AC High Voltage Electrostatic Voltmeter, Kilo Volt Meter Electrostatic Voltmeter, Kilo Volt Meter, HV Divider kV Meter upto 150 kV   At 50 Hz 110000 48300 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
26 AC High Voltage Electrostatic Voltmeter, Kilo Volt Meter Electrostatic Voltmeter, Kilo Volt Meter, HV Divider kV Meter upto 200 kV   At 50 Hz 137500 64000 For each additionalrange Single range and upto 10 calibration points. Tuning / Adjustment
Charges extra @25%
27 AC High Voltage H V Probe H V Probe   0 to 30 kV   At 50 Hz 31500     upto 10 calibration points
28 Voltage Burden Burden Box P T Burden Box   Upto 550 VA [110V, 110V/sqrt(3)]   At 50 Hz 30800 17600 Foreach additionalvoltage (110V or 110V/1.73) upto 10 calibration points
29 Current Burden Burden Box C T Burden Box   Upto 550 VA (5A)and upto
110 VA (1A)
  At 50 Hz 30800 17600 For each additional Current (1A or 5A) upto 10 calibration points
30 Capacitance and Loss facor (Tan Delta) High Voltage Capacitorsand Tan Delta Bridge C & Tan Delta Bridge/ Schering Bridge/ Transformer Arm Ratio
Bridge
  C= 10pF - 100µF, Tan Delta = 0.00001 to 1.0 (Subject to current
limitation)
  At 50 Hz 96600     Tuning/Adjustment Charges extra @30%
31 High Voltage Capacitance High Voltage Capacitors High Voltage Capactors   10pF - 100µF and upto 10kV (Subject to current limitation)   At 50 Hz 16250      
32 High Voltage Capacitance High Voltage Capacitors High Voltage Capactors   10pF - 100µF andupto
30kV (Subject to current limitation)
  At 50 Hz 31900      
33 High Voltage Capacitance High Voltage Capacitors High Voltage Capactors   10pF - 100µF and upto100kV (Subject to current limitation)   At 50 Hz 80300      
34 High Voltage Capacitance High Voltage Capacitors High Voltage Capactors   10pF - 100µFand upto
150kV (Subject to current limitation)
  At 50 Hz 110000      
35 High Voltage Capacitance High Voltage Capacitors High Voltage Capactors   10pF - 100µF andupto
200kV (Subject to current limitation)
  At 50 Hz 137500      
36 Tan Delta High Voltage Capacitors Tan Delta Box   Tan Delta Box upto 50kV(Subject to current limitation)   At 50 Hz 16350      
37 Tan Delta High Voltage Capacitors Tan Delta Box   Tan Delta Box upto 100kV(Subject to current limitation)   At 50 Hz 23600      
38 Tan Delta High Voltage Capacitors Tan Delta Box   Tan Delta Box upto 150kV(Subject to current limitation)   At 50 Hz 33000      
39 Tan Delta High Voltage Capacitors Tan Delta Box   Tan Delta Box upto 200kV(Subject to current limitation)   At 50 Hz 39600      