Calibration Charges: D2.03b, LF, HF Voltage, Current & Microwave Standards (w.e.f. 01.04.2018)
Calibration Charges: D2.03b, LF, HF Voltage, Current & Microwave Standards (w.e.f. 01.04.2018)
Frequency, RF Voltage, RF Power, Effective Efficiency, Calibration Factor, Voltage Amplitude, AC Voltage  & Frequency and Voltage Amplitude & Frequency
Sl. No. Parameter Item Type / Group Item Name Alias Name Range No. of Points for Calibration Limitation / Condition Charges per Item Rs. Additional Charges Rs. Description for Additional Charges Remarks, if any
1 Frequency Frequency Counter Frequency Counter Frequency meter    6 Frequency points for Frequency / Period  Stability >1.0E-8 37700 5600 For each additional frequency   For 'Basic Oscillator' calibration of this counter, see "Time & Freqency" Parameter 
2 Frequency Frequency Counter Universal Counter       6 Frequency points for Frequency / Period & Time Interval   52100 8400 For each additional frequency    
3 RF Voltage 
Voltmeter Selective Microvoltmeter

 
Level Meter Up to 1000 MHz 6 Frequencies with 50 ohm Input Impedance   81500 12500 For each additional frequency    
4 RF Voltage
Voltmeter RF Millivoltmeter   Up to 1000 MHz 6 Frequencies per probe   81500 22300 For each additional probe    
5   RF Power & Frequency Signal Generator  Synthesizer Sweep Oscillator 1 MHz to 18 GHz  5 frequencies for Power Level, Time Base Accuracy & Frequency Response Type N connector 81500 8400 For each additional frequency    
6   RF Power & Frequency
Spectrum Analyser Spectrum Analyser Wave Analyser 1 MHz to 18 GHz  5 frequencies for Power Level, Time Base Accuracy & Frequency Response Type N connector 81500 8400 For each additional  frequency    
7 Effective Efficiency / Calibration Factor / RF Power Power Meter RF Power Meter with  Sensor   1 MHz to 18 GHz 3 Frequencies with one Sensor (Effective Efficiency/ Calibration Factor/ RF Power) Type N connector 28100 8400 For each additional frequency    (For VSWR, separate charges under VSWR/reflection coefficient parameter)
8 Effective Efficiency / Calibration Factor Coaxial Thermistor Mount Coaxial Thermistor Mount Power Mount 1 MHz to 18 GHz 1 Frequency Type N connector 55900 18400 For each additional frequency   (For VSWR, separate charges under VSWR/reflection coefficient parameter)
9 Effective Efficiency / Calibration Factor RF Power Transfer Standard RF Power Transfer Standard   1 MHz to 18 GHz 1 Frequency Type N connector 17100 16200 For each additional frequency   (For VSWR, separate charges under VSWR/reflection coefficient parameter)
10 Effective Efficiency / Calibration Factor RF Power Transfer Standard RF Power Transfer Standard   1 MHz to 50 GHz 2 Frequency 2.4mm connector 74000 37000 For each additional frequency   (For VSWR, separate charges under VSWR/reflection coefficient parameter)
11 Effective Efficiency / Calibration Factor  Power Meter RF Power Meter with sensor   1 MHz to 50 GHz 3 Frequency with one sensor 2.4mm connector 40500 13500 For each additional frequency   (For VSWR, separate charges under VSWR/reflection coefficient parameter)
12 AC & DC Voltage & Current, Frequency, Resistance & Verification Procedures PMU-CAL System Phasor Measurement Unit Calibration System PMU-CAL ACV ~ 1000V ; ACC ~ 20A ; DCV ~100V; DCC ~ 5A ; GPS Freq : 10MHz; Resistance Calibration procedures as per the respective parameters   1200000     As per ISO 17025
13 Voltage, current and Frequency PMU Phasor Measurement Unit (P / M Class) PMU 50 to 100 V  1A to 5A @ 50Hz / 60Hz Report rates: 10,25 & 50 Automated test sets as per IEEE standards for P or M class Configuration of PMU @ CSIR-NPL should be done by User 14000 14000 For each additional  Level/ class / reporting rate Testing as per IEEE std. C37.118.1a-2014