Sl. No. Parameter Item Type / Group Item Name Alias Name Range No. of Points for Calibration Limitation / Condition *Present Charges per Item Rs. *Present Additional Charges Rs. Description for Additional Charges Remarks, if any
1 Frequency Frequency
Counter
Frequency
Counter
Frequency
meter
  6 Frequency points for Frequency /
Period
Stability
>1.0E-8
41500 6200 For each additionalfrequency For 'Basic
Oscillator' calibration of this counter, see "Time & Freqency"
Parameter
2 Frequency Frequency
Counter
Universal Counter     6 Freq. points for
Frequency / Period & Time Interval
  57300 9200 For each additionalfrequency  
3 RF Voltage
Voltmeter Selective Microvoltmeter
Level Meter Up to 1000 MHz 6 Frequencies with 50 ohm Input Impedance   89700 13800 For each additionalfrequency  
4 RF Voltage
Voltmeter RF Millivoltmeter   Up to 1000 MHz 6 Frequencies per probe   89700 24500 For each additional probe  
5 RF Power & Frequency
Signal Generator Synthesizer Sweep Oscillator 1 MHz to 18 GHz 5 frequencies for Power
Level, Time Base Accuracy & Frequency Response
Type N connector 89700 9200 For each additionalfrequency  
6 RF Power & Frequency
Spectrum Analyser Spectrum Analyser Wave Analyser 1 MHz to 18 GHz 5 frequencies for Power
Level, Time Base Accuracy & Frequency Response
Type N connector 89700 9200 For each additionalfrequency  
7 Effective Efficiency / Calibration Factor / RF Power Power Meter RF Power Meter withSensor
  1 MHz to 18 GHz 3 Frequencies with one Sensor (Effective Efficiency/ Calibration
Factor/ RF Power)
Type N connector 30900 9200 For each additionalfrequency (For VSWR, separate
charges under VSWR/reflection coefficient parameter)
8 Effective Efficiency / Calibration Factor Coaxial Thermistor Mount Coaxial Thermistor Mount Power Mount 1 MHz to 18 GHz 1 Frequency Type N connector 61500 20200 For each additionalfrequency (For VSWR, separate
charges under VSWR/reflection coefficient parameter)
9 Effective Efficiency / Calibration Factor RF Power Transfer Standard
RF Power Transfer Standard
  1 MHz to 18 GHz 1 Frequency Type N connector 18800 17800 For each additionalfrequency (For VSWR, separate
charges under VSWR/reflection coefficient parameter)
10 Effective Efficiency / Calibration Factor RF Power Transfer Standard
RF Power Transfer Standard
  1 MHz to 50 GHz 2 Frequency 2.4mm connector 81400 40700 For each additionalfrequency (For VSWR, separate
charges under VSWR/reflection coefficient parameter)
11 Effective Efficiency / Calibration Factor / RF Power Power Meter with sensor RF Power Meter withSensor
  1 MHz to 50 GHz 3 Frequencies with one Sensor (Effective Efficiency/ Calibration
Factor/ RF Power)
2.4mm connector 44600 14900 For each additionalfrequency (For VSWR, separate
charges under VSWR/reflection coefficient parameter)
12 AC & DC Voltage and Curent at different configuration, Line
Frequency, GPS Validation.
PMU CAL System/ Phasor Measurement Unit Calibrator System/ PMU-CAL ACV~1000V ACC~20A DCV~150 DCC~5A GPS Lime Freq Full Calibration @ pre selected points Congiguration of System at CSIR-NPL should be done by USER 1200000   For each additionalfrequency  
13 TVE, FE, RoFE PMU - M class Phasor Measurement Unit (M Class) PMU 50V to 150V 1A to 5A 50/60 Hz 25/50 fps One Level /class/reporting rate Congiguration of PMU at CSIR-NPL should be done by USER 14000 14000 For each additionalfrequency  
14 TVE, FE, RoFE PMU - P class Phasor Measurement Unit (P Class) PMU 50V to 150V 1A to 5A 50/60 Hz 25/50 fps One Level /class/reporting rate Congiguration of PMU at CSIR-NPL should be done by USER 14000 14000 For each additional frequency  